
49
Data Parameters Long Parameter Names
ENGINE RUN WITH MIL
ACTIVE
Conditions for this counter:
1. Resets to zero when MIL state changes from deactivated to
activated by this ECM.
2. Accumulates counts in minutes if MIL is activated (ON)
3. Does not change value while MIL is not activated (OFF)
4. Resets to zero if diagnostic information is cleared either by service
$04 or 40 warm-up cycles without MIL activated
5. Does not wrap to zero if value is maximum (65535).
ENGINE SPEED Engine speed as calculated by the ECM, based on various signals.
EQUIVALENCE RATIO
Bx-Sy
Status of the oxygen sensor in V or as a ratio. Designed for linear or
wide-ratio oxygen sensors.
See also PID $14 and up or $34 and up.
EVAP SYSTEM VAPOR
PRESSURE
Evaporative system vapor pressure, if used by the control module. Can
be obtained from a fuel pressure sensor in the tank or in the
evaporative system vapor line.
FUEL LEVEL INPUT
Shows the nominal fuel tank liquid fill capacity. For gaseous fuels the
percentage of usable fuel capacity is shown. May either be obtained
directly from a dedicated sensor, or calculated by the ECM based on
other sensor signals.
FUEL PRESSURE GAUGE
Shows the fuel rail pressure at the engine relative to the atmosphere
(gauge pressure).
FUEL SYSTEM x
Fuel System 'x' does not normally refer to injector banks. It is intended
to represent different fuel systems (for multi-fuel vehicles) that can
independently enter and exit 'Closed Loop'. 'Closed Loop' means the
fuel control system uses the oxygen sensor signal. Banks of injectors
on a V engine are generally not independent and use the same closed
loop criteria.
IGNITION TIMING
ADVANCE
Ignition timing spark advance for cylinder #1. If timing is retarded, the
value will be negative.
INTAKE AIR
TEMPERATURE
Shows the intake manifold air temperature as obtained from a sensor
or as calculated by the ECM (using other inputs).
INTAKE MAP
Shows the absolute pressure in the intake manifold as measured by
the MAP sensor.
LONG TERM FUEL TRIM
BANK x
Shows the correction used by the Closed Loop and Open Loop fuel
algorithm at the moment this parameter is requested. Negative values
indicate a 'lean' condition, positive values a 'rich' condition. 0%
correction will be shown if no correction is used in Open Loop.
NR OF WARM-UPS SINCE
DTCs CLEARED
A warm-up cycle is valid if the coolant temperature rises, after starting
the engine, at least 22 °C/40 °F and reaches at least 70 °C/160 °F (60
°C/140 °F for Diesel engines). The maximum number is 255. To set to
0, reset all DTCs.
O2S BANK x, SENSOR y
Shows the presence of oxygen sensor number 'y' per bank 'x' (group of
cylinders). Sensor 1 is closest to the engine
O2S CURRENT BANK x,
SENSOR y
Status of the oxygen sensor in mA or as a ratio. Designed for linear or
wide-ratio oxygen sensors.
See also PID $14 and up or $24 and up.
Table 7-1 Long parameter names (sheet 3 of 4)
Parameter Description for long parameter
Kommentare zu diesen Handbüchern